Product Review
Benefit
Specific disconnection alarm securing protection
High cost performance, low failure rate
Cool Capacity is 50W / ℃
Forces circulation, 9L cooling tank capacity
It can extend the using life of laser tube and ensure the engraving effect better
Installation
Industrial cooling machine's installation is very simple, the new machine for the first time using, you can install it as following steps
A. Open the package and check the machine and all accessories
B. Open the mouth screw on the top of machine, add cooling water (Please don't power the machine without water)
C. Connect the inlet and outlet hose between water cooler and laser engraving machine
D. Connect the power cable, turn the power switch (Note: Don't let the water overflow)
E. Check the radiator water level again (Keep the distance between water level and mouth is 80 - 150mm)
Maintenance
Cooling machine used in long term, you should open the machine and clean the dust in order to ensure good heat dissipation
You can use non - corrosive antifreeze if you are in the northern cold regions
Note
30W DC pump, pgoda connector
Its emitting rate is lower than 60%
Mainly used on the equipment for heat exchange between the heat and the air environment
Remarks: CW3000 water chillers are equipped high speed fans inside, NOT able to control the water temperature
Power Supply: 110V
Current: 0.9A (AC100 - 120V)
Tank Capacity: 9L
Cooling: Radiator that forces the wind cooling
Amount of Cooling: 50W / ℃
Way of Circulation: Water pump forces circulation
Maximum Flow: 9L / min
Maximum Pumping Lift: 10m
Inlet and Outlet: External Dia.: 10mm brass connector
Protection: Flow alarm