Parameters:
Product name: Temperature and Humidity Controller
Product model: SHT2000
Supply voltage: AC 110~230V
Power supply frequency: 50/60Hz
Temperature range: -20~60°C
Humidity measurem...

Buy Now From Amazon

Product Review

Parameters:
Product name: Temperature and Humidity Controller
Product model: SHT2000
Supply voltage: AC 110~230V
Power supply frequency: 50/60Hz
Temperature range: -20~60°C
Humidity measurement range: 0%~100%RH
Temperature measurement accuracy: 0.3 °C
Humidity measurement accuracy: 3%
Output control: relay output
Output power: MAX 10A


Setting method:
Start value < stop value (program automatically determines working mode is heating/humidifying mode)
Start value > stop value (the program automatically determines the working mode is cooling/dehumidifying mode)

Heating/cooling mode setting:
Setting (starting temperature): Press and hold the –² button to start the temperature flashing. Use –²– key to set the starting temperature value.
Setting (stop temperature): Press and hold the – button to stop the temperature flashing. Use –²– to set the stop temperature value.

Humidifying/ Dehumidifying Mode Setting:
Setting (start humidity): Press and hold –³ key to start the humidity value flashing. Set the humidity to start by –³ –½ key.
Setting [stop humidity): Press and hold –³ key to stop the humidity value flashing, and set the humidity to stop by –³ –½ key.

  • 【Overview:】Diymore SHT2000 AC 110~230V10A temperature and humidity controller, just make your life more convenient.
  • 【Heating Mode:】Start value < stop value (program automatically determines working mode is heating/humidifying mode). For example, controlling the water heater, heat to 65℃ to stop, the temperature drops back to 50℃and start heating again
  • 【Cooling Mode:】Start value > stop value (the program automatically determines the working mode is cooling/dehumidifying mode). For example, using in the farm, the fan is ventilated to 26℃to stop, the temperature is raised to 30℃ and the ventilation is started again
  • 【Humidifying Mode:】Start value < stop value (program automatically determines working mode is heating/humidifying mode). For example, fresh supermarket humidification, control humidifier 50% RH began to humidify, humidified to 80% RH to stop humidification
  • 【Dehumidifying Mode:】Start value > stop value (the program automatically determines the working mode is cooling/dehumidifying mode). For example, workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification

Similar Products

eTopxizu 12v 30a Dc Universal Regulated Switching Power Supply 360w for CCTV, Radio, Computer Project AC Infinity AXIAL 1225, Quiet Muffin Fan, 115V 120V AC 120mm x 25mm Low Speed, for DIY Cooling Ventilation Exhaust ProjectsLEDMO Power Supply, Transformers,LED Adapter, 12V, 5A Max, 60 Watt Max, for LED Strip